How a Buyer Commissions an Independent δ¹³C Test
Direct answer
How can a buyer get coconut sugar tested independently for added sugar?
Choose a laboratory accredited to ISO/IEC 17025 whose accreditation scope includes δ¹³C analysis, send it a sealed and labelled sample with a record of who handled it, and ask for a report that states the δ¹³C value, the method and its uncertainty. Read the value against the proposed −24.1‰ maximum for coconut sugar (Rogers et al., Food Analytical Methods, 2021).
The steps are written for a buyer’s QA team. They belong to authenticity and adulteration testing of coconut sugar.
1. Direct answer: three steps
-
Pick an accredited laboratory.
ISO/IEC 17025 sets requirements for the competence, impartiality and consistent operation of laboratories, and accreditation bodies use it to assess and accredit them (ISO, ISO/IEC 17025:2017, as read 5 November 2026). Accreditation is granted for an agreed scope, so check that the report is “covered by the scope of accreditation” (EA, The EA MLA, as read 5 November 2026), not only that the lab is accredited. Results from labs accredited by ILAC MRA signatories are accepted by the other signatories (ILAC, ILAC MRA and Signatories, as read 5 November 2026).
-
Send the sample under your own control.
Take it from a sealed bag in the lot, seal and label it with the lot number, and keep a record of who held it until the lab signs for it. FDA’s own sampling manual asks for a sample “sealed in such a manner as to maintain its integrity as evidence, with a clear record of its chain of custody” (FDA, Investigations Operations Manual 2026, chapter 4, as read 5 November 2026).
-
Ask for a full report.
The δ¹³C value in ‰, the method and instrument, the measurement uncertainty, and the lab’s report number.
2. What to ask the lab
The buyer question, answered
“We want our own test, not the supplier’s. What do we ask the lab?”
- Is δ¹³C analysis of sugar on your accreditation scope, and under which accreditation number?
- Which method and instrument do you use: isotope-ratio mass spectrometry with an elemental analyser (EA-IRMS)?
- What measurement uncertainty do you report for δ¹³C?
- How much sample do you need, and how should it be packed?
- How long does the result take, and will the report carry its own number so it can be confirmed with you?
3. Reading the number
A result at or below −24.1‰ is within the proposed −24.1‰ maximum for coconut sugar; a higher (less negative) result suggests added cane or corn sugar (Rogers et al., Food Analytical Methods, 2021). The test cannot detect beet sugar, which is also a C3 plant (Ždiniaková and de la Calle, European Food Research and Technology, 2020).
Sources
- Rogers, Phillips, Yuan et al., Food Analytical Methods 14:1250–1255 (2021), DOI 10.1007/s12161-021-01967-9; AOAC 998.12 analog · peer-reviewed · fetched
- International Organization for Standardization (ISO) · ISO/IEC 17025:2017 — General requirements for the competence of testing and calibration laboratories · standards-body · fetched
- European co-operation for Accreditation (EA) · The EA MLA · standards-body · fetched
- International Laboratory Accreditation Cooperation (ILAC) · ILAC MRA and Signatories · industry-body · fetched
- US Food and Drug Administration (FDA) · Investigations Operations Manual 2026, Chapter 4 — Sampling · government · fetched
- European Food Research and Technology (Springer), 2020 — authors at the European Commission Joint Research Centre · Feasibility study about the use of element profiles determined by ED-XRF as screening method to authenticate coconut sugar commercially available · peer-reviewed · fetched